秦建柱 
华能东方电厂,海南东方 572600 
[摘 要] 首批国产超I名界350 Mw机组锅炉投产以来,均出现了排烟温度明显高于设计值的问 
题,其主要原因是锅炉空气预热器吸热量不足。华能东方电厂通过对省煤器、空气预热 
器改造,降低了排烟温度,每台机组年可节约标准煤约3 850 t,减少二氧化硫生成量85 
t以上,减少二氧化碳排放量9 000 t以上。 
[关词] 350 MW机组;超临界;锅炉;排烟温度;空气预热器;节能改造 
[中图分类号] TK223 [文献标识码] B 
[文章编号] 1002—3364(2011)06—0049—03 
IDol编号] 10.3969/j.issn.1002—3364.201 1.06.049 
CAUSE ANALYSIS AND TECHNICAL RETROFIT DUE TO HIGHER 
TEMPERATURE oF FLUE GAS DISCHARGED FRoM BoILER 
oF SUPERCRITICAL 350 MW UNIT 
QIN Jianzhu 
Huaneng Dongfang Power Planl,Dongfang 572600,Hainan Province,PRC 
Abstract:Since putting the boiler of supercritical 3 50 MW unit in Huaneng Dongfang Power Plant into 
operation,the problem of discharged flue gas temperature being substantially higher than the designed value has appeared.The main cause is insufficient absorbed heat in the boiler’S air preheater.Through retrofit of the economizer and the air preheater,the temperature of discharge flue gas has been de— creased,the saved standard coal of each unit call reach about 3850 t in one year,reducing formation of 
sulfer dioxide above 85 t,decreasing emission of CO2 above 9000 t. 
Key words:350 MW unit;supercritical;boiler;te-mperature of discharged flue gas;air preheater;energy 
saving retrofit 
超临界350 MW机组适用于较小电网容量条件、 烧、Ⅱ型布置的直流锅炉,其中瑞金电厂2台机组分别 煤炭资源相对短缺及煤价较高的地区[ 。首批国产超 
于2008年12月15日、2008年12月18日通过168 h 
临界350 Mw机组共4台,均配置HG一1100/25.4— 试运行,华能东方电厂2台机组分别于2009年6月2O 571/569型一次中间再热、单炉膛、前后墙对冲旋流燃 
日、2009年12月5日通过168 h试运行。 
作者简介:秦建柱(1975一),男,工程硕= ,工程师,长期从事锅炉运行及燃煤火电厂节能降耗研究。 