同济大学 流体力学 水泵实验串并联 实验报告

发布时间:   来源:文档文库   
字号:
性能曲线实验记录(A单泵
转速n=2850/分钟Z=0.72
测值
压力表真空表流量Q功率表P1有效功率
计算参数轴功率
项目序号
PM(Mpa)10.06020.07030.08040.09050.09260.11870.13380.14790.15410
0.160
A
Q(L/s
9.04.1659.33.9749.53.8259.83.74610.33.44811.03.20311.62.89612.42.67613.7
2.36
P(Mpa(L/s(Kw)扬程(m
V(Kw)0.0263.8451.0539.4890.3580.0243.5731.04610.3050.3610.0203.2651.00010.9170.3500.0183.0880.97911.7330.3550.0142.80.94311.5290.3170.0092.3610.88513.6700.3170.0021.9260.81014.4860.2740.0001.3510.69515.7090.2080.0000.9520.65216.4230.1530.000
0.638
0.601
17.035
0.107
离心泵串联实验记录(AB泵)
转速n=2850/分钟B
串联机组
H2(mQ(L/sPVA(MpaPMB(Mpa)扬程(m9.04.1650.0340.0509.2859.33.9740.0300.06510.4079.53.8250.0280.08412.1409.83.7460.0260.10213.77210.33.4480.0220.13016.21911.03.2030.0190.16018.97211.62.8960.0160.18821.52112.42.6760.0130.20823.25513.7
2.36
0.010
0.230
25.192
(Kw)0.7580.7530.7200.7050.6790.6370.5830.5000.4690.433
Z=0.72
4.1653.9743.8253.7463.4483.2032.8962.6762.36
H1(mQ(L/s

14.71.72314.71.7230.0020.27829.2711.723
分析:初始流量较大时,两个泵串联时的扬程不等于单泵的扬程之和,但随着流量的减小,两。原因可能是流量大时,损失较大。

N0.72
姓名:学号:
效率
47.19647.94648.54950.40746.62649.67346.91541.59432.66224.631
理论扬程(H1+H2)
18.018.619.019.620.622.023.224.827.4
18.000
H单泵Q-H曲线
16.000
(m
14.00012.000
10.0008.000
6.000Q-H曲线
4.0002.0000.000
0.000
1.000
2.000
3.000
4.000
5.000QL/s
PKw
单泵流量——功率曲线
0.8000.700
0.6000.5000.400
0.300Q-P曲线
0.2000.100
0.000
0.000
1.000
2.000
3.000
4.000
5.000
QL/s
效率单泵流量——效率曲线
60.000
%50.00040.00030.000

29.4
30.000
流量——效率曲线
20.00010.000
小,两数值近似相等
0.000
0.0001.0002.0003.0004.0005.000
QL/s
Hm35.000
30.00025.000
双泵串联Q-H曲线
20.00015.00010.0005.0000.000
0
1
2
3
4
5
Q-H曲线
QL/s

本文来源:https://www.2haoxitong.net/k/doc/ff53345db4daa58da0114ae7.html