Power Consumption Test SOP(功耗测试作业规范)
>>>>>>>>>ISDDQAEE0004---PowerConsumptionTestSOP
>>>>ISDDQAEE0004---功耗测试作业规范
1.TestPurpose
[测试目的]
Thepurposeofthistestistoverifythepowerconsumptionontheallmodesthatmeetthespecificationsornot.
[本测试的目的是确定机器在各种工作模式下的功耗是否符合要求.]
2.TestSampleSize
[测试抽样大小]
Thetestquantityis1-2pcs.
[测试数量为1-2台]
3.TestImplement/Equipemnt
[测试工具/测试设备]AIOsamplesx1
Brandironx1
Oscilloscope:Lecory454x1[AIO样机一台,烙铁一台,Lecory454示波器一台]
4.TestLocationandEnvironmentControl
[测试场所和测试环境]
22±5℃,55±5%RH[温度范围:22.0±5℃,湿度范围:55±5%R.H.]5.TestProcedure
>>>>[测试步骤]
step1.Checkthebasefunctionoftestmachineanddefinemeasurepoints.(as5Vand24V;[步骤1.检查整机的功能并且确定测试点.(如5V与24V]step2.DismantletheESSboardandfindmeasurepoints.[步骤2.拆下机器主板,找到测试点位置.]
step3.Solderthewiretothemeasurepoint.(TheBrandiron'stemperatureisabout300℃-400℃willbebetter.)Thewireistheshorter,thebetter.(about2points.
[步骤3.焊接测试线到相应测试点.(烙铁温度在300-400度之间为宜.连接线越短越好.(2个点]step4.Assemblethemachineandfixthetestwire.[步骤4.组装好机器并固定好测试线.]
step5.CheckthemachineFirmwareanddownloadthelateFirmware.[步骤5.确定机器FW,更新到最新版本.]
step6.Trytorunthemachine2-3times,makesureitsmooth.[步骤6.试运行2-3次机器,确保机器能正常运行.]
step7.Measuretheconsumptionof+5Von17modes(sleep,standby,poweron/off,FBcolorscan300dpi,FBcolorscan600dpi,FBB&Wscan300dpi,FBB&Wscan600dpiADFcolorscan300dpi,ADFcolorscan600dpi,ADFB&Wscan
300dpi,ADFB&Wscan600dpi,FBcolorcopy,FBB&Wcopy,ADFcolorcopy,ADFB&Wcopy,colorprint,B&Wprint。),(ThemainpointisthesettingontheOscilloscopebasetimeandmeasurement.Thetestbasetimesettingrelatetotheeveryrunningperiodthatshouldbeaslongeraspossibleincludetherunningperiod.ThetestvoltagemeasurementissettingononeofthirdoroneofsecondactualVoltage.
[步骤7.测量在+5V电压在17种模式的功耗.(最主要的是进行示波器的量程和时基的设置.测试时基的设置与每一个运行周期有关,必须尽可能地包含在运行周期内.测试电压量程设置为1/2-1/3实际电压值.]step8.Measurethe+24Vtestpointon17modesasthesame.[步骤8.用相同方式测试+24V电压的17种模式.]
step9.Storethetestgraphandrecordthetestdata.(asbottomshow)[步骤9.保存测试图并记录下测试数据.(如页底所示]6.TestRecordTable
>>>>>>>>>[>>>>测试记录表]
FBscanADFscanFBcopyADFcopyPrinting24VPowerpowe
SleeStandUnicolorcolorB&WB&WcolorcolorB&WB&WcoloB&ConsumptiorB&colopbycolorB&Wt
non/off